Acceptance Criteria and Out-of-Specification Results

Acceptance criteria define the results a material is expected to meet under specified tests. An out-of-specification result falls outside an applicable criterion. Reading it properly requires the criterion, method and result together, followed by the documented investigation and decision where available. A later passing result does not explain an earlier failure by itself.

Find the criterion before judging the result

ICH Q6A describes a specification as a set of tests, analytical procedures and acceptance criteria. Criteria can be numerical limits, ranges or other requirements. [A3] A headline such as “99%+” cannot supply all those details. The purity-claim page should be read alongside the relevant lot documents.

For your review, put the specification reference and revision beside the report reference. Check the named attribute, method, units, reporting basis and criterion. If the documents use different terms, resolve the difference before assigning a pass or fail. An HPLC area percentage and a mass-based assay are not interchangeable; identity, purity and assay explains why.

Separate an outside result from an unanswered question

The following fictional examples assume the stated method and reporting basis apply. The numerical comparisons are deliberately simple; they are not recommended acceptance limits.

Separate an outside result from an unanswered question
Invented criterion and report entryReading of the supplied informationWhat to record next
HPLC area result at least 98.0%; reported result 97.8%Below the stated criterionOriginal report reference and investigation status
HPLC area result at least 98.0%; reported result 98.0%Meets this inclusive numerical thresholdOther required attributes remain separate
Named solvent no more than 5 mg/kg; report says less than 10 mg/kgCannot determine conformity from this reporting boundAsk for a result or reporting capability that resolves the 5 mg/kg criterion
Identity must match the specified reference; identity field blankNo identity conclusion is suppliedAsk whether the result was omitted, pending or not obtained

“Less than 10” includes values on either side of 5. It therefore cannot be rewritten as either “passes” or “fails” that invented limit. A missing result is likewise not a measured failure. Preserve these distinctions in a review log rather than compressing every unresolved item into “OOS”.

For a borderline result, request the laboratory's applicable reporting and decision rules. Do not add rounding, uncertainty allowances or extra decimal places yourself. The figures displayed on a certificate may not contain everything needed to reproduce its conformity decision.

Read the investigation as an explanation

FDA's OOS guidance concerns pharmaceutical production. It calls for documented investigation and does not treat a suspected laboratory error as established without supporting evidence. It also distinguishes the test result from the eventual batch decision. [A4] These are useful questions when reading records; this guide does not assert that those pharmaceutical requirements govern a particular research-material supplier.

A useful review note identifies what happened and what remains unresolved. For example: “Report DEMO-R17 gives 97.8% against the stated 98.0% minimum. The issuer says an investigation is open; no conclusion has been supplied.” This invented wording records the discrepancy without diagnosing its cause or declaring a final release outcome.

Ask for the explanation linking the observed result, the evidence examined and the conclusion. If the issue concerns chromatographic integration, the complete chromatogram and processing context matter; reading an HPLC chromatogram describes the relevant report fields. A replacement PDF without an explanation leaves the reason for the change unanswered.

A retest needs a stated purpose

FDA's guidance distinguishes retesting the original sample material from resampling additional material. It rejects repeated testing until a pass appears, expects a justified plan and requires retention of the original data. Passing retests alone do not invalidate an initial OOS result when no laboratory or calculation error is identified. [A4]

Imagine that a second fictional report gives 98.3% after the original 97.8%. Those two numbers do not tell you whether the same sample was retested, a new sample was collected, a calculation was corrected or an unrelated lot was tested. Do not choose the higher figure or create an average as a substitute for the issuer's documented explanation.

A retest needs a stated purpose
Question for the issuerWhy it matters to the reader
Which original report and sample does the follow-up address?Prevents a later document being attached to the wrong event
What prompted the additional work?Separates an investigation from an unexplained replacement number
What changed, and which records remain valid?Makes the relationship between the original and revised conclusion explicit
What is the current decision and who issued it?Keeps the analytical finding separate from the material's recorded status

Keep the result and disposition linked

Disposition is the recorded decision about the material. Consult batch release, quarantine and rejection for that distinction. A test result, an investigation in progress and a release decision should not be presented as three names for the same event.

Retain the original report, any revised version and the accompanying explanation together. If you need clarification about a supplied lot, use technical support with the exact identifiers and discrepancy. The quality-documentation hub provides the wider evidence routes. An unavailable procedure is a gap in the material reviewed here, not proof that a supplier has no procedure.

References

These sources support the stated analytical and documentation principles. Pharmaceutical guidance and environmental procedures have their own scope; their citation does not establish supplier compliance, actual testing or a lot result. Manufacturer documentation does not identify a Knockout Labs supplier.

  1. [A3] ICH Q6A: Specifications, Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products. ICH. 6 October 1999. Section 1.2, specification definition; section 3.2.1(b), identity.
  2. [A4] Investigating Out-of-Specification (OOS) Test Results for Pharmaceutical Production. FDA. May 2022, revision 1. Sections III–V; investigation, retesting, resampling and conclusions.

Sources accessed 23 October 2026. Examples, calculations and record ledgers are original educational illustrations with invented inputs.